CRT |
- Configuration
and useful screen :
6 inch rectangular screen
with internal graticule,
8X10div.(1div = 1cm) marking
for measurement of rise time, 2mm
subdivisions along the central
axis.
- Acceleration potential : +1.9kv approx.(ref.
Cathode)
- Phosphor : P31
- Focusing : provided
- Trace rotation : provided
- Scale illumination : provided
- Intensity control : provided
|
 |
|
Z-AXIS
INPUT(INTENSITY
MODULATION) |
- Input signal
: positive going signal decreases +5Vp-p
or more signal
cases intensity noticeable
modulation at normal
intensity setting
- Bandwidth : DC to 2MHz(-3dB)
- Coupling : DC
- Input impedance : 20kз - 30kз typical
- Maximum input voltage : 30V(DC + peak
AC) |
 |
|
VERTICAL
DEFLECTION
|
- DC coupled(-3dB)
: DC to 40MHz normal / DC to 7MHz magnified
- AC coupled(-3dB) : 10Hz to 40MHz normal
/ 10Hz to 7MHz magnified
- Modes : CH1, CH2, ADD, DUAL(CHOP :
Time/div. switch from 0.2s
to 5ms, ALT : Time/div.
switch from 2ms to 0.2レs)
- Deflection factor (normal): 5mV/div.
to 5V/div. in 10 calibrated steps of
1-2-5
sequence. Continuously variable
between steps at least 1:2.5, Deflection
factor (5MAG): 1mV/div.to
1V/div. in 10 calibrated steps
- Accuracy : normal 【3%, magnified :
【5%
- Input impedance : approx. 1Mз in parallel
with 30pF【3pF
- Maximum input voltage : direct 250V
(DC + peak AC)
- Input coupling : AC, GND, DC
- Rise time : 8.8ns or less (50ns or
less in 5MAG)
- CH1 output : 20mV/div. into 50з /
DC to 10MHz(-3dB)
- Polarity inversion : CH2 only
- Signal delay : delay cable installed
|
 |
|
HORIZONTAL
DEFLECTION |
- Sweep mode
: A, A int B, B, B triggered, X-Y
- Time base A : 0.2レs/div. to 0.2s/div.
in 19 calibrated steps of 1-2-5
sequence uncalibrated continuous
control between steps
at least 1:2.5
- Hold-off time : variable with the
hold-off control
- Time base B : 0.2レs/div. to 20レs/div.
in 7 calibrated steps of 1-2-5
sequence uncalibrated continuous
control between steps
at least 1:2.5
- Delayed sweep : 1 div. or less to
10 div. or more
- Delayed time jitter : better than
1:20,000
- Sweep magnification : 10 times(maximum
sweep rate : 20ns/div.) 50ns/div.
or 20ns/div. of A time
base are uncalibrated
- Accuracy : 【3%, additional error for
magnifier : 【2% |
 |
|
X-Y OPERATION |
- Single
trace X-Y : X-axis = CH1(SA), Y-axis
= CH2(SB)
- Dual trace X-Y : X-axis = CH1, Y-axis
= CH2
- Sensitivity : 1mV ~ 5V/div. 【 5%
- X-Y phase difference : 3∑ or less
as DC to 50kHz |
 |
|
READOUT
FUNCTION |
- Cursor
readout function : ツV, voltage reference
ツ-REF, ツT,
time reference ツ-REF, ツ1/T,
frequency reference ツ-REF
- Effective cursor range from center
graticule :
within 【3div. on vertical
/ within 【3div. on horizontal
- Resolution : 1/25 div. |
 |
|
DIGITAL STORAGE
FUNCTION |
- Display
/ save memory : 1000 words / channel
or 1000 words / channel X 2
- Acquisition memory : 5レs/div. to 20s/div.
: 2000 words / channel or 0.2レs/div.
to 20レs/div. : 1000 words
/ channel
- Vertical resolution : 25 point / div
- Horizontal resolution : 100 point
/ div
- Maximum sampling rate : 20M sampling
/ sec
- Digital bandwidth single shot event
: 5MHz
- Repetitive event : 40MHz
- Data acquisition method : NORM mode(storage
the data each time trigger) / |
 |
|
AVG |
mode(averaging
form 4 to 256 times) / ROLL mode
data is continuously stored on the CRT)
/ HOLD mode(data is held for the NORM,
AVG or ROLL) / SINGLE mode (waveform
is held after stored) / AMAG mode(simultaneously
displaying the original waveform and
its magnified waveform) / GNG mode(judgement
and comparing of acquisition signal)
- Data save : up to two storage data
can be saved.
Saved data can be recalled
to the display whenever required.
- Pre-trigger : variable (0.04 div.
step)
- Plotter : plotter output of the CRT
displayed information
to an HP-GL plotter via
RS-232C interface
- Data output : RS-232C
- Magnified display : X 10 by time/div.
switch or MAG switch
- Sweep time : 0.2レs/div. to 20s/div.
(repetitive signal: 0.2レs/div. to 2レs/div.)
/ roll mode:0.5s/div. to
20s/div. /
ALT mode : 0.2レs/div. to
0.5ms/div. / CHOP mode : 1ms/div. to
20s/div.
|
 |
|
CALIBRATOR |
- Probe adjustment
: approx. 1kHz frequency, 0.5V(10%)
square wave with
40-50% duty ratio
|
 |
|
POWER SUPPLY |
- Line voltage
range : 100V(90-110V) with 250V 2A fuse,
120V(108-132V)
with 250V 2A fuse, 220V(198-242V)
with 250V 1A fuse or 230V
(207-250V) with 250V 1A
fuse
- Line frequency : 50/60Hz
- Power consumption : approx. 70W |
 |
|
PHYSICAL
CHARACTERISTICS |
- Weight
: 8kg
- Dimension : 320mm(W) X 140mm(H) X
430mm(L) |
 |
|
OTHERS |
- Accessories
including : Operation manual, Spare
fuse, Power cord
- Optional accessories (sold separately):
Probe, RS-232C software package
(LS-3000) |
|
|